Der Current Sensor misst den elektrischen Strom und gibt den Wert über die serielle Schnittstelle aus
//Basic energy monitoring sketch - by Trystan Lea
//Licenced under GNU General Public Licence more details here
// openenergymonitor.org
//Sketch measures current only.
//and then calculates useful values like
//apparent power and Irms.
//Apparent power is calculated from set Vrms.
double Vrms=240.0;
//Setup variables
int numberOfSamples = 3000;
//Set current input pin
int inPinI = 1;
//Current calibration coeficient
double ICAL = 1.0;
//Sample variables
int lastSampleI,sampleI;
//Filter variables
double lastFilteredI, filteredI;
//Power calculation variables
double sqI,sumI;
//Useful value variables
double apparentPower,
Irms;
void setup()
{
Serial.begin(9600);
}
void loop()
{
for (int n=0; n<numberOfSamples; n++)
{
//Used for offset removal
lastSampleI=sampleI;
//Read in current samples.
sampleI = analogRead(inPinI);
//Used for offset removal
lastFilteredI = filteredI;
//Digital high pass filters to remove 2.5V DC offset.
filteredI = 0.996*(lastFilteredI+sampleI-lastSampleI);
//Root-mean-square method current
//1) square current values
sqI = filteredI * filteredI;
//2) sum
sumI += sqI;
}
//Calculation of the root of the mean of the current squared (rms)
//Calibration coeficients applied.
Irms = ICAL*sqrt(sumI / numberOfSamples);
//Calculation power values
apparentPower = Vrms * Irms;
//Output to serial
Serial.print(apparentPower);
Serial.print(' ');
Serial.println(Irms);
//Reset current accumulator
sumI = 0;
}